In your CCNA investigation study, you figured out PortFast? and the situation it can direct to if configured on the incorrect port! Suitable just for swap ports joined straight to a solitary host, PortFast? permits a port running STP to go straight away from blocking to forwarding mode.

A Cisco router will present you you a warning when you set up PortFast?:

SW1( config) #int speedily /5

SW1( config-if) #spanning- tree portfast

% Warning: portfast should to just be permitted on ports joined to asingle host. Linking hubs, concentrators, switches, bridges, and so on. to this interface when portfast is allowed, can end result in temporarybridging loops. Use with Warning

% Portfast has been founded up on FastEthernet0/five but will just

When the interface is in a non-trunking fashion, have ultimate end result.

SW1( config-if) #.

Not only will the swap warning you about the correct usage of PortFast?, nevertheless you will have to place the port into get hold of strategy prior to PortFast? will get end result.

There is a prospect - just a likelihood - that an specific is very likely to cope with to url a change to a port operating Portfast. The following scenario is that there may perhaps perfectly be a new root bridge most well-liked - and it could be a switch that is just not really even in your community!

BPDU Guard protects to this devastating chance. If https://youtu.be/8M9KlVs1F0g?si=J3Tuii8sKqX2TFwH comes in on a port which is controlling BPDU Guard, the port will be shut down and set into blunder disabled condition, unveiled on the switch as err-disabled. A port positioned in err-disabled condition wants to be reopened by hand.

BPDU Guard is off on all ports by default, and is manufactured it attainable for as exposed mentioned here:.

SW1( config) #int fast /5.

SW1( config-if) #spanning- tree bpduguard make it possible for for.

It truly is a good idea to make it possible for BPDU Guard on any port you happen to be working PortFast? on. There is definitely no price tag in overhead, and it does quit the hazard of a swap sending out BPDUs into a port configured with PortFast? - not to spot out the chance of a change not under your command having to be a root adjust to your community!

% Warning: portfast need to to just be designed it feasible for on ports related to asingle host. Linking hubs, concentrators, switches, bridges, and so on. There is an likelihood - just a possibility - that an additional human being is heading to tackle to be part of a swap to a port functioning Portfast. If any BPDU arrives in on a port that's doing work BPDU Guard, the port will be shut down and set into oversight disabled state, confirmed to on the swap as err-disabled. A port put in err-disabled point out demands to be resumed manually.